Feasibility of the Use of an Ultrasonic Depth Gauge in a Stilling Well for a Telemetric System 'Source Title' Hydrosoft'84; Hydraulic Engineering Software; Proceedings of a International Conference

By IVETIC, M

Bibliographic details

Summary

The water level measuring system presented in the paper features several advantages over the clasical solution (large stilling well-horizontal connecting pipe), The advantages are: lower cost of structure, Lower risk of clogging, easier maintenance. The required dynamic response of the measuring system can be achieved by proper choosing the dimensions of its parts. Adding the twin ultrasonic depth gauge to the system both resolution and accuracy in level gauging are increased. The measuring system is feasible for incorporation into telemetric data acquisition system. The system damps high frequency changes, whereas the selective post processing of the acquired data has to be applied by the computer for very low frequency level changes.