"Design of Vortex Tube Sediment Ejectors for the Jamrao Canal" 'Source Title' Proceedings of ISM/R Symposium, Lahore 11-13 April 1993 Volume V
Bibliographic details
Summary
The Jamrao Canal takes water from the Nara Canal at the Jamrao weir, 180 km from Sukkur Barrage on the River Indus. For the past 60 years, bed levels in the head reaches of the Jamrao canal have reported a rise of about 8.0ft. There is a proposal to increase the design discharge of the Nara Canal from 10,000 cusecs to 18,000 cusecs and of the Jamrao Canal from 4500 cusecs to 5700 cusecs. The channels are suffering badly from sediment deposits. The Jamrao Canal is to be twinned. The possibility of retuming water to the Canal System and the availability of 3.5 m (11.25 ft) head of water has made the use of vortex tube sediment ejectors feasible for both the Jamrao Canal and its twin. Extracted sand will be trapped in a settling basin and pumped out by dredger to a disposal area. A few experiments were carried out on a physical model to confirm the performance of the design of vortex tubes, the transition structure located between the outlet pipes and settling basin, and self cleaning of the sediment deposits in the tubes.