Hydrologic Monitoring and Tubewell Performance, Khairwala Sub Unit Lower Rechna Remaining Project (1990-91)

Bibliographic details

Summary

The actual discharge capacity of the tested tubewells is 11.46 percent more than designed capacity. The median specific capacity of tubewells tested during 1990-91 had showed decrease from 146 to 121 1pm/dm, there by showing the reduction of 17.12 percent for operating tubewells. In 1990-91, the specific capacity of 15 and 4 tubewells reduced from 1 to 15 percent and 16 to 25 percent respectively. Seven tubewlls showed reduction between 26 to 50 percent. Tubewells showing reduction from 16 to 50 may be undertaken for rehabilitation. The wire to water efficiency of tested tubewells ranged from 33 to 58 percent. Efficiency values in the range of 33 to 58 percent are hardly indicative of very efficient functioning of these tubewells after the short operational span and needs attention. The disaster area (0-1.52m) during October 1990 and June 1991 was nil. Area within the range of (1.5 to 3.0 m) decreased from 12.53 to 2.90 percent during June 1991 as compared to June 1990. It expected that depth to watertable would go down further after the removal of tubewell's defects and keeping all the tubewells in good running condition. (L.B.)