Hydrologic Monitoring and Tubewell Performance in Scarp Khairpur 1977-78
Bibliographic details
Summary
The salient conclusions derived from the analysis presented in the report are: ; 1. The utilization of the project tubewells on the basis of available pumping capacity is only 50 percent during the year under report. ; 2. Average watertable depth during April 1977 and 1970 was 6.9 feet and during October 1977, the depth was 6.0 feet. Thus the objective of maintaining the watertable at 7 feet below ground level at all seasons has not been achieved fully due to low pumpage. ; 3. The median value of specific capacity of tubewells has decreased by about 33 percent since acceptance. ; 4. Three hundred and twenty seven tubewell, 60 percent of the tested tubewells, have registered a decrease of more than 20 percent in specific capacity. Four percent of the tubewells in fresh zone and 10 perent of the tubewells in saline zone have shown reduction in specific capacity of more than 60 percent. Total 65 tubewells, 13 percent of the total tested tubewells, have shown reduction in specific capacity of more than 60 percent. ; 5. The pumping capacity of the project tubewells has decreased by about 29 percent since acceptance and by about 15 percent with respect to their designed discharge. ; 6. Three hundred and two tubewells, 63 percent of the tested tubewells, have registered a decrease of more than 20 percent in their discharge since acceptance test. Eight percent of the tubewells in saline-zone have shown reduction in discharge of more than 60 percent whereas the corresponding figure in fresh zone is only 1.3 percent. Total 20 tubewells, 6 percent of the total tested tubewells, have shown reduction in discharge of more than 60 percent. ; 7. One hundred and forty tubewells, 29 percent of the tested tubewells, have registered a decrease of more than 20 percent in their discharges as compared to their desinged discharges. Twelve tuebwells, 4 percent of the tubewells tested in saline zone, have shown reduction in discharge of more than 60 percent whereas none of the tubewells in fresh zone has shown reduction in discharge of more than 60 perent. ; 7. One hundred and forty tubewells, 29 percent of the tested tubewells, have registered a decrease of more than 20 percent in their discharges as compared to their designed discharges. Twelve tubewells, 4 percent of the tubewells testd in saline zone, have shown reduction in discharge of more than 60 percent whereas none of the tubewells in fresh zone has shown reduction in discharge of more than 60 perent. ; 8. So far 5 tubewells have failed due to bore damage and have been rebored and put into operation. ; 9. Out of 304 tubewells tested for sand contents only one tubewells, B-49, was found to have sand blowing problem and has been stopped. ; 10. The performance of stainless steel strainers has been better in fresh zone and that of fibre glass strainers has been better in saline zone. The overall combined results of fresh and saline zones show that the performance of fibre glass screens is better than that of stainless steel screens.