Electric Resistivity Survey in Khanpur (Dam) Area

Bibliographic details

Summary

In order to locate a suitable site for the tubewell installation in the area under report electrical verticals sounding were executed at various suitable sites to known the subsurface hydrological conditions and thickness of the alluvium. The high resistivities of the subsurface formations indicate higher values of formation factor ranging from 5 to 15. Thus the encountered formations with high resistivities are considered somewhat emented, with low-permeability as confirmed by the poor yield given by the aforesaid test hole. As already pointed out it is a closed area, the recharge is very poor, even the river, Haro does not appear to contribute any significant recharge. Under such conditions there is a little chance of installing a successful tubewell unless it gets recharge from the lake formed by the Dam.