PakCat catalogue record

"Iron Contaminated Groundwater and Land Drainage; Prospect for Durable Drainage Systems in Iron Contaminated Soil" 'Source Title' Proceedings of 5th International Drainage Workshop, February 8-15, 1992, Lahore Volume II

By Bergedalen, Johns

Bibliographic details

Summary

Drainage of artesian fields is a great challenge. Ordinary tile drainage systems fail to function in most artesian fields due to precipitation of iron oxides in the drainpipes. through more than 20 years of experiments we have developed drainage systems, which function well under most Norwegian conditions, even in artesian fields. For investigation the following methods are recommended. Piezometric observation for mapping of groundwater level, and for determination of vertical and horizontal groundwater flow. Analyses of redox potential pH, iron content and relative content of Fe++ and Fe+++ for estimation of iron clogging hazards. Underground profile mapping, especially for finding aquifer or other structures from where the groundwater can be efficiently drained. Artesian water pressure is always related to water bearing strata of high transmissivity in rocks or soils. If possible, drain directly from these permeable layers, preferably from great depth (3-15) by vertical well pipes and collector pipes at 2.5-3.5 m depth. Iron oxide will not cause problems in these types of drainage systems. In some cases the water bearing strata of high transitivity (aquifers) end outside the waterlogged field. the water then seeps through semi-pereable ground from the aquifer to the waterlogged area downstream. The cure is then to place the tile drains in voluminous filter envelopes as deep as possible, (2.5-3.5 m depths) in the waterlogged area. Iron clogging problems are then reduced due to lack of oxygen at these depths. In some areas there will still be some precipitation of iron in the pipes. Tile should, therefore, end in an inspection pit from where the pipes could be cleaned in case of clogging. Oxygen is to be restricted from entering the pipes. This can be done by fitting a raiser (air lock) to the tile inlets or to the main drain outlet from the sump in order to raise the waterlvele above the drain outlets. If the waterlogging is restricted to small areas, spot drainage may be the solution. Dig a deep hole in the centre or slightly upstream from the wet spot. Line it with permeable canvas sheet or geotextile and fill in some few m of gravel. Install a drain pipe through the gravel package and raise it up and connect it to a drain at 2.0-3.0 m depth. Put canvas on the top of the gravel, before filling the soil back, to avoid soil penetration into the gravel.