Evaluation of Aquifer Parameters Using a Neutron Moisture Probe, 1969
Bibliographic details
Summary
The results of a special aquifer test using a neutron mousture probe performed at Khangah Dogran Reclamation area tubewell KD/209 are reported. Aquifer parameters were determined by the known aquifer-test methods and some of these parameters have also been calculated by the use of a neutron-moisture probe. The discrepancies inherent in the use of mathematical formulas used for evaluation of aquifer charactgeristics have been discussed briefly. These formulae are based on mathematical models with simple geometrical boundaries to make the treatment of differential equations amenable to easy calculations. In most cases the boundary conditions do nto agree with the conditions prevailing in the field. This disagreement between field conditions and conditions assumed int he derivation of formula gives erroneous results. Howwefer, there is some agreement in the value of T by different methods, but the storage coefficent varies to a great extent. The use of a neutron moisture probe makes the evaluation of some of the aquifer parameters very simple. The parameters are evaluated without the use of mathematical formulas, and values are directly determined. Ghourdour distributary which is 363 feet from the tubewell and which has a discharge of 40 cubic ft/sec has no effect on the drawdown pattern and thus does not contribute to the tubewell discharge.