"A Computerized One-step Outflow Method for Measurement of Soil Water Diffusivity" 'Source Title' Proceedings of the International Symposium on Applied Soil Physics in Stress Environment, January 22-26, 1989 Islamabad
Bibliographic details
Summary
A study was conducted to develop an automatic system for measuring and recording water outflow collected during the one-step technique. For the one-step methods, saturated soil cores in contact with a ceramic plate are subjected to a pressure and the resultant outflow of water is collected and measured at selected time intervals until outflow ceases. During this study, outflow was converted to a proportional electrical signal by directing the outflow into a 2m long glass tube (7mm dia) connected to a pressure transducer which precisely monitored the hydraulic head created by the outflow volume. The signal monitored by pressure transducer was transmitted to a computer through a datalogger. A BASIC program for the computer was created to collect and record the signals at selected time intervals. For this experiment the intervals were 1 minute apart at the begining and were gradually increased to 12 hours after one week. The sensitivity and accuracy of the system was tested by observing the response of transducers at hydraulic heads of 0.00, 0.32, 0.64, 0.96, 1.28 and 1.60m for 20 replications. The analysis of data showed thatstandard deviation was 5 mm (Corresponding to 0.19cm3) which suggests that this technique is sufficiently senstive for measurements of the outflow.