PakCat catalogue record

Design Characteristics of Line Source Drip Tubes 'Source Title' Drip/trickle Irrigation in Action; Proceedings of the third International Drip/trickle Irrigation Congress Volume Vol.1

By Boswell, M.J

Bibliographic details

Summary

The uniformity of water application in a micro irrigation system depend large degree upon the pressure sensitivity of the emitting devices use pressure sensitivity of line source drip tubes depends upon whether they the orifice type or the capillary type. The pressure sensitivity of devices is measured by X, the emitter flow exponent. Orifice tube and other fully turbulent flow devices have an X variety one half which means that the flow rate will vary in proportion to the root of the pressure. Thus, a large change in pressure produces a small in flow. For example, a pressure variation of 20% will result in variation of approximately 10%. Capillary tubes and other fully laminar flow devices have an X values of which means that the flow rate will vary directly with pressure. this that a pressure variation of 20% will result in a flow variation of flow rate must be corrected for temperature. The significant difference in X values between capillary and orifice type tubees means that for a given uniformity criterion, the allowable pressure envelope for orifice type drip tubes will be approxmately two large as the envelope for capillary control drip tubes. Thus, the lines, because the size and length of manifolds, and the allowable length run of lateral lines, depends upon the size of the design pressure envelope.