PakCat catalogue record

Design of Land Drainage by Wallrus 'Source Title' Journal of Engineering and Applied Sciences Volume Vol.14, No.1 January-June 1995

By Daulat Khan

Bibliographic details

Summary

This paper presents the computer use of MicroRAT procedure for design of agricultural drainage network. The 150 hectares catchment area were selected in London (U.K) for draining of farm land. A trapezoidal channel of 1:2 was designed for carrying of drain water. Gradients are designed to give adequate self-cleansing velocities. Sizes are designed using the rational formula to cope with the peak flows. Ten trapezoidal channels were designed to carry out the drain water. The minimum conduit having bottom width of 375 mm and depth of 100 mm. The channel remove excess water from 15 hectares of land. The design flow velocity is 0.389m3 sec-1 while the channel capacity is 0.398 m-3 sec-1. Thus the design to channel capacity ratio is 98.73%. The maximum conduit size are 750 mm and 500 mm. It drains excess water from 150 hectares. The design flow velocity is 2.740 m3 sec-1 and channel capacity is 3.286m3 sec-1. The ratio of design flow to channel capacity is 83.38%. It is obvious from calculation that the ratio of design flow to channel capacity reduces by increasing the catchment area.