Hydrologic Monitoring and Tubewell Performance, R.Q.B. Link Canal 1990-91

Bibliographic details

Summary

The project tubewells are drawing 12.2 percent more than the design discharge. The higher entrance velocities caused due to higher discharges could end up in the early choking of screens. The situation should be controlled by reducing discharge with the help of sluice valves. The median specific capacity of tubewell tested during 1990-91 had shown decrease of 22 percent. In 1990-91, the specific capacity of 12 and 18 tubewells reduced from 1 to 15 percent and 16 to 25 percent respectively. 24 and 3 tubewells have undergone reduction of 26-50 percent and 51 -70 percent respectively. Moreover 2 tubewells have decreased from 71-100 percent. None of the tested tubewells was found giving sand.