Hydrologic Monitoring and Tubewell Performance Studies in Mona Reclamation Project July 1965 - June 1967
Bibliographic details
Summary
The discharge and specific capacity of the tubewells test during 1966- 67 are summarized and specific capacity of wells at the time of acceptance of the tubewells. For the analysis presented in this report wells in the Mona area are separated according to performance into three general classes; 1 Tubewells which show a decrease in discharge irrespective of the change in specific capacities; 2) tubewells that show a decrease in the discharge but no reduction in specific capacity. Figure 14 has been prepared to indcate the magnitude of deterioration in tubewell discharge and specific capacities. Based on this information it appears that about 5 percent of the tubewells are seriously effected and their specific capacities have decreased from 20 - 70 percent. The total number of tubewells whose specific capacities have been effected is 24 i.e about 18 percent. The pumping capacity of 73 tubewells has decreased and the reduction is approaximately 16 percent of their designed capacity. Projected over the whole scheme the average reduction in the pumping capacity is approximately 7 percent. With the present information collected it is not possible to determine the cause of fall in the discharge of those tubewells whose specific capacities have not changed. Probably this can be attributed to mechanical adjustment or general lowering of the water table or both of them. A list of all tubewells which have been effected by a decrease in discharge or specific capacity is given in table 8-10.