Hydrologic Monitoring and Tubewell Performance, Shorkot Kamalia Pilot Project Scarp-V, 1990-91
Bibliographic details
Summary
The aggregate discharge of the tested tubewells is 23.1 percent less than their designed discharge. In 1990-91, the specific capacity of 2,3 and 11 tubewells reduced upto 15 percent, 16 to 25 percent and 26 to 50 percent respectively.Moreover, 18 and 35 tubewells under-went reduction from 51-70 percent and 71-100 percent since acceptance test. Rehabilitation of deteriorated tubewells registering reduction from 16 to 70 percent may be under taken at the earliest. 35 tubewells registering reduction from 71-100 percent are recommended for replacement. The median specific capacity of tubewells tested during 1990-91 had shown decrease from 139 to 42 1pm/dm (93 to 28 gpm/ft) of draw down there by showing decrease of 70 percent for operating tubewells. None of the tested tubewells was found giving sand. The wire to water efficiency of 11 tubewells was less than 30 percent due to frictional losses in their pumping units. In June 1991, the disaster area has decreased 3.1 percent as compared to June 1990 which was due to 24.8 m.m. less rainfall in 1990-91 as compared to previous year. The main causes of an increase in disaster area in October 1990 as compared to October 1989 was due to more canal supplies and less pumpage in 1990-91 as compared to 1989-90.(L.B.)