Summary
Resistivity sruvey in this respect was accomplished by establishing vertical electrical soundings at 14 selected locations along three profile lines, weir site area and the power house area. The interpreted resistivity results reveal different resistivity response at deeper depths in the two areas. The weir sites soundings show characteristic increasing resisitvity with depth and the interpreted lithologic model of this area basically comprises of two units. The upper unit represents the over burden while the lower unit is interpreted to be bedrock with a weathered top. The soundings of the power house area show a characteristic decrease in resistivities with depth. The interpreted model of this area can also be viewed in two units. The upper unit constitutes the overburden upto 50 to 65 meters depth. The lower unit shows a departure from the behaviour usually observed for bedrock in the area. Therefore, the conclusive lithologic description of this unit could not be established.