Optimization of Snyder's Synthetic Unit Hydrograph Parameters for Watersheds in Pakistan 'Source Title' Journal of Engineering and Applied Sciences Volume Vol.13, No.1 January-June 1994
Bibliographic details
Summary
In this paper the applicability of HEC-1 to optimized the Synder's unit hydrograph parameters has been demonstrated. Meanwhile base length in hour (B1) of unit hydrographs for the test watershed was also noted. Sixteen gauged sample watersheds, in the range of 145 to 3250 square kilometers are selected. Rainfall data for 65 storm events are provided to the model for optimization of one hour duration Synder's Unit hydrographs parameters and base length. For these sample watershed the average value of Cp was found in the range between 3.00 and 6.82, Tpr between 2.80 and 8.43 hours and B1 between 33 and 137 hours. The consistency of the model was also checked by determining the coefficient of variation and it was found that the HEC-1 gives the consistent results.