PakCat catalogue record

Interpretation Of Tracer Tests Of Long Duration 'Source Title' Proceedings of Regional Conference on Water Resources Management, Isfahan, Iran, 1995

By Mousavi, S.F

Bibliographic details

Summary

Two sets of tests were performed in combination with long duration pumpmg tests at El Cabril site (Spain), a gneissic formation. Applied tracers were Zinc EDTA, lode, Eosine, Rhodamine WT, and Amino G Acid. Injection of tracers took place 3 or 4 days after the start of pumping, when it was assumed that the velocity field around the well was constant. Only one type of tracer was used in each injection well. The tests are interpreted using CONFLO computer code (Carrera and Walter, 1985) which allows automatic estimation of transport parainet6rs (dispetsivity and accessible porosity) by optimizing the fit between measured and calculated concentrations. This program assumes that the medium is isotropic and the discharg'& s constant. A coefficient of depletion is estimated using concentration data at each injection wel i'. The results for set one showed that dispersivities range from 3.5 to 22.7m, porosities;from 0.0013 to 0.16, and Peclet numbers from 0.35 to 1.62. The comb'meu, porosity was 0.007. For the second set, the porosities range from 0.00025 to 0.049, dispersivities from 1.5 to 12.3 m, and Peclet numbers from 0.11 to 0.53. The Peclet numbers suggest the medium to be highly heterogeneous at the test scale, the most important conclusion is that the anisotropic nature of the site leads to marked directional depedence of estimated porosity.