PakCat catalogue record

"Effect of Trench Versus Trencnless Drain Pipe Installation on Drainage System Performance 'Source Title' Proceedings of 5th International Drainage Workshop, February 8-15, 1992, Lahore Volume III

By Kanwar, R.S

Bibliographic details

Summary

A field study was conducted to evaluate the performance of two methods of subsurface drain installation (chain trencher and trenchless drain plow) by collecting data on water table depths, subsurface drainage flows, water quality, and saturated hydraulic conductivities. Experiments were conducted for a period of 12 years. Evaluation of the water table data indicates that subsurface drains installed with a trencher maintain lower water table depths throughout the growing season in comparison to the areas drained by the trenchless method but these differences are steadily decreasing with time. The data on saturated hydraulic conductivities of the soil profile around the drains indicate that the plow method may have caused compaction in the immediate vicinity of the drain resulting in the lower hydraulic performance of the drainage system for 4-5 years after installation. But the overall data on water table depths, drainage outflows, and water quality indicate that the trenchless method can perform satisfactorily over a wide range of soil condition if the soil-moisutre conditions are ideal at the time of drain installation.