PakCat catalogue record

Calibration of Drainpipe Weir: Thesis for the Degree of M.Sc. in Water Resources Management

By Hassan Zia Munawar

Bibliographic details

Summary

This study was performed to test 8" sharp crested weir in a drainpipe and develop a head-discharge relationship. The drainpipe weir is a simple sharp crested weir installed at the out fall of a subsurface drain into a sump or a manhole. After taking observations in the laboratory, a relationship between head and discharge was developed for horizontal crest at a pipe slope of 0.1%. Regression analysis was used to check the reliability of the results. The weir was also tested on titled positions and for different slopes of the pipe to check the sensitivity of the relationship to these parameters. The head-discharge relationship for drainpipe weir was also checked for submerged condition. The water surface profiles were also measured in the pipe for 0.1% slope. The comparison of laboratory test results of this study with those of Brussel's work shows the same trend with some minor differences.