PakCat catalogue record

Drag Reduction im Pipe Turbulent Flow Using a new Industrial Cleaner 'Source Title' Journal of Engineering and Applied Sciences Volume Vol.5, No.1

By Mansour, A.R.

Bibliographic details

Summary

A new multi-purpose industrial cleaner has been experimentally tested as drag reducer in turbulent pipe flow of water.Experiments showed that a consentration of 0.2 ppm of the new substance was sufficient to produce measureable appreciable drag reduction.Afriction reduction upto 36 percent has been noted in pipe flow with an additive concentration of 1 ppm. In this paper the efects of pipe diameter aditive concentration and the variation of Reynolds Number on drag reduction have been experimentally investigated.