Economics and Performance of Different Types of Strainers in Good Quality Water
Bibliographic details
Summary
Tubewells with differnt types of strainers commenced to be installed at Niazbeg Field Research Station, from 1959 to find out their performance and economics. Water quality of the site is good from irrigation point of view. Its conductivity varies from 650 to 900 PPM; and its reaction is alkaline as pH varies from 7.8 to 8.2. The tubewell strainers tested to-date are Munj, Coir, Brass, gravel packed i.e. Ghafoor, P.V.C. Tubewell with Munj Strainer failed after about two years working. The other tubewells are working well with decrease in dicharge at the rate of 1.6% to 2.7% per year at 18 ft. depression head. On the bais of their performance recorded so far the economics of coir string strainer and PVC have been found better. The tubewells were run for 200 hours per year for testing their performance. Now it has been planned to run the tubewells 500 - 700 hours per year to get the results rapidly and to observe the effect of increasing the time of tubewell operation on the decrease in discharge due to incrustation formation.(LB)