PakCat catalogue record

Field Calibration of Gate Structures for Discharge Measurement 'Source Title' Proceedings National Seminar On Water Resources Development And Its Management In Arid Areas, Quetta, Held By Pakistan Council Of Research In Water Resources, Water Resources Research Centre, October 6-8, 1990 Volume Vol. 1

By Gandarillas, C A

Bibliographic details

Summary

In most water conveyance systems, there are numerous structures that can be calibrated for the purpose of water measurement. Usually, the most common structure in a delivery network is gate structure which a=can be easily calibrated. Other common discharge structures that can be calibrated are culverts, inverted siphons, drop structures, and wasteways. In fact, any type of structure that constricts the flow can be fileld calibrated for discharge measurement. Gate structures behave hydraulically as orifices, which can have either modular or non-modular flow. By means of A mathematical orifice they can be calibrated within a reasonable degree of accuracy.