"Learning to Lay Subsurface pipe drains the right way in the drainage-IV Project, Faisalabad, Pakistan" 'Source Title' Proceedings of 5th International Drainage Workshop, February 8-15, 1992, Lahore Volume III

By Achthoven, T.Van

Bibliographic details

Summary

No earlier experience of installing subsurface pipe drains in the he difficult soil conditions of the project area existed. It was decided to complete a pilot sump before the contractor would start the subsurface drainage works. This was done to ascertain the problems likely to be encountered in the soil-water conditions of the project area and to test the trenching machines. The sump construction pipe-laying operations, and flow of effluent in the pipe was monitored closely. Valuable information on the soil- water behavior, gravel feeding, gravel envelope performance and operation of the trenchingmachines were obtained. When the contractor started the main works, more problems were encountered while installing the pipe drains, with regard to the behavior of the gravel envelope, soil stability and upward pressure of the water in the he trenches. Model tests of the gravel envelope were conducted and some experimental pipe drains were installed. This paper briefly describe these experiences and efforts of the consultants, contractor and the project staff to overcome the problems in the given environment.