Planning Laboratory Investigations for Oxidation Ponds 'Source Title' Oxidation Ponds Planning Design and Operation, Proceedings of a Pannel 8-9 September, 1986
Bibliographic details
Summary
A small laboratory housed in a single room at the plant side with one trained chemist assisted by plant operater and an assistant is sufficient to carry out most of the analytical work on oxidation. To detect any abnormality the daily record of physical aspects as well as meteriological data should be recorded on the given proformas. Remedial measures for mosquitoes and insects breeding and the presence of toxic matreial in the influent are suggested. Different sample collecting techniques are given for physical, chemical, bacteriological and biological examination of pond samples ordinary pyrex glass bottle or polythene bottles of 2 liter capacity are sufficient, for special study, samplers should be used. Waste water characteristics should be detremined much before the start of pond operation. The parameters to be estimated for detremining pond efficiency are given. For research purpose more parameters may be selected from the optional determinands. For procedures, latest edition of standard method for the examination of water and waste water by AWWA, APHA and WPFC should be used. The results should be recorded on the performas given for each type of ponds.