PakCat catalogue record

Analog Model Study of the Relationship between the proposed groundwater withdrawals and the decline of water table in Scarp-6 Area (Panjnad - Abbasia Canal Project) 1969

By Gilani, Maqsood Ali Shah

Bibliographic details

Summary

Salinity control and Reclamation Project-6 (SCARP-6) is one of a series of projects in the Northern Zone of Indus Plain to reclaim determinated lands, control subsurface drainage, and provide full supplemental irrigation water requirements by expliotation and management of ground water supplies. The essential feature of this programme is a proposed network of tubewells. Groundwater withdrawals will serve the dual purpose of helping to supply irrigation requirements and of providing subsurface drainage. This report summarizes the effects of the proposed operation of the project for a period of 50 years considering two different hydrologic boundary conditions. The project area consists of two distinct zones on the basis of ground water quality. Net withdrawal has been proposed only from the zone of non-saline ground water. The study has been done using an Electric Analog Model of SCARP- 6 Area (Panjnad Abbasia Canal Project). The two systems investigated are, firstly, ont he basis of an average overall project area distribution of most of the pumpage and recharge; and secondly, by revisiong the manner of input of recharge to the model using exact loctions and amounts for each source. Projected decline in ground water levels for 20 years and 50 years of contnous project operation have been contoured. Some of the typical time-drawdown curves have also been included in the report. The electric analog analysis indicates that the maximum decline in groundwater levels after 50 years of continous project operation would be about 60 and 78 feet for the first and second case of study respectively. There will be continous rate of decling in the areas of high drawdown and in the area of further distance from recharge line sources. however, in the areas of farther distance from recharge line sources. However, in the areas of close proximity to constant head and constant recharge line sources the ground water levels tend to come steady after earlier time of pumpage. It is found that the pumping in the Non-Saline zone will effect the ground water levels in the saline-zone. Within the saline zone the average decline will be approximately 10 feet and 20 feet respectively, for 20 years and 50 years of project operation. As a consequence of the development programme there will be a ground water flow from the saline zone towards the centre of pumping in the Non-Saline zone.